105210-5340 ZEXEL 9 440 610 491 BOSCH SUPPLY PUMP 9440610491 1052105340 8970811810


 

Information supply pump

BOSCH 9 440 610 491 9440610491
ZEXEL 105210-5340 1052105340
ISUZU 8970811810 8970811810
105210-5340 SUPPLY PUMP
Rating:
44
Buy SUPPLY PUMP 105210-5340 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

1. [1] 152051-0920 PUMP HOUSING
5. [1] 152100-1120 PUMP PLUNGER
6. [1] 152102-0400 COMPRESSION SPRING
7. [1] 152105-1500 CAPSULE
8. [1] 139526-0000 GASKET
10. [1] 152111-2820 TAPPET
10/2. [1] 152112-0100 ROLLER
10/3. [1] 152113-0700 BEARING PIN
10/4. [2] 152114-0400 SLIDER
14. [2] 152115-0200 VALVE BODY
14. [2] 152115-0200 VALVE BODY
15. [2] 152116-0200 COILED SPRING
15. [2] 152116-0200 COILED SPRING
16. [1] 152118-0900 ADAPTOR
18. [1] 029631-6060 O-RING
19. [1] 029631-6060 O-RING
20. [1] 152121-0200 LOCKING WASHER
25. [1] 152200-5420 HAND PRIMER
30. [1] 152300-5620 EYE BOLT
32. [1] 029111-4050 CAPSULE
33. [1] 152350-7820 PIPE
35. [2] 029341-4080 GASKET
36. [1] 026514-2040 GASKET
49. [1] 152118-1500 CONNECTOR
51. [1] 139514-0300 GASKET

Include in #1:

101491-0710 as SUPPLY PUMP

Cross reference number

Zexel num
Bosch num
Firm num
Name
105210-5340 
9 440 610 491 
8970811810  ISUZU
SUPPLY PUMP
* K 14GC F/P




Information:


Fig. 5-Output TerminalStart engine and run at approximately 1500 rpm. Connect voltmeter negative lead to alternator ground terminal and connect positive lead to alternator auxiliary terminal (Fig. 4). Voltmeter should read 15.4 volts. Now move voltmeter positive lead to alternator output terminal (Fig. 5). Voltage reading should be 14.4 volts.If voltage at auxiliary terminal is 15.4 volts, while at the output terminal it is 12 volts or battery voltage, the isolation diode is open. Replace it. Test No. 4 - Field Draw Test (Key Switch Off)Detach regulator and let hang by red and black wires. DO NOT allow regulator to touch the output terminal. If test ammeter is not equipped with a 1/4-ohm resistor, a 1/4-ohm resistor should be connected in series with the ammeter to protect the meter.
Fig. 6-Field Terminal - Test 4Disconnect green field wire from field terminal. Connect ammeter from output terminal (2, Fig. 6) to field terminal (1). Current reading should be 2 to 2.5 amps. If less than this, check brushes and slip rings. Test No. 5 - Checking Alternator and Regulator With Regulator Disconnected (Key Switch On - Engine Running)Disconnect the regulator from the connector. Disconnect the green wire from the field terminal. Connect a jumper wire from the output terminal (2, Fig. 6) to the field terminal (1). Connect voltmeter negative lead to ground terminal and connect voltmeter positive lead to regulator terminal (3).Start engine and run at slow idle. This test isolates the defect to either the alternator or regulator.If voltage at regulator terminal rises to 15-16 volts now, when it did not with regulator connected in Test No. 3, then the regulator is defective and should be replaced.If voltage does not rise at regulator terminal and the field circuit was okay in Test No. 4, then the stator or rectifier diodes are defective. See Section 16, Group 1672 for testing diodes and stator. Test No. 6 - Alternator OutputIf not using JDST-23 tong-type ammeter, disconnect wire from alternator output terminal and connect ammeter from alternator output terminal 2, Fig. 6 to starter solenoid "Bat" terminal. Connect voltmeter negative lead to ground and connect positive lead to output terminal (2, Fig. 6). Connect a carbon pile resistor (turned off) to the battery.Run engine at approximately 1400 rpm. Use a master tachometer to measure rpm. Adjust carbon pile to obtain maximum alternator output at 13 to 15 volts. Ammeter should read 25 amps or more for the 35 amp alternator and 43 amps for the 55 amp alternator. Test No. 7 - Testing RegulatorThe regulator must be checked with an alternator that is in good condition. If the alternator is questionable, check it as previously instructed.Connect voltmeter with 0.1 volt accuracy to the alternator output terminal and ground terminal (Fig. 5). With charged batteries and the regulator brought to operating temperature (fifteen minutes operation), the voltage should be as specified for the surrounding air temperature. See chart below. If battery is partially discharged, it may be necessary to connect a

Have questions with 105210-5340?





Group cross 105210-5340 ZEXEL

 
 

Mitsubishi 

9 440 610 553 
NP-FP/KE-AS 
ME730808 
SUPPLY PUMP

Mazda 

9 440 610 401 
TM0113VF0 
SUPPLY PUMP

Isuzu 

9 440 610 427 
8970811820 
SUPPLY PUMP
105210-5340  
9 440 610 491 
8970811810 
SUPPLY PUMP
9 440 610 492 
8970832620 
SUPPLY PUMP
9 440 610 544 
8970851480 
SUPPLY PUMP
9 440 610 428 
8970942250 
SUPPLY PUMP
9 440 610 178 
NP-FP/KE-AD 
 
SUPPLY PUMP

Isuzu 

9 440 610 962 
8970894430 
SUPPLY PUMP
9 440 610 429 
8970937610 
SUPPLY PUMP
9 440 610 583 
NP-FP/KE-A 
 
SUPPLY PUMP
Back to top