Buy 105210-4271 ZEXEL 9 440 610 033 BOSCH SUPPLY PUMP 9440610033 1052104271 1157500180


 

Information supply pump

BOSCH 9 440 610 033 9440610033
ZEXEL 105210-4271 1052104271
ISUZU 1157500180 1157500180
105210-4271 SUPPLY PUMP
Rating:
21
Buy SUPPLY PUMP 105210-4271 zexel genuine, new aftermarket engine parts with delivery

Compare Prices: .

As an associate, we earn commssions on qualifying purchases through the links below
£154.55
 

23 Mar 2018

Bosch: Bosch
Bosch 9440610033 Supply Pump
Bosch Professional Car Service is for the complete equipment of your car

Scheme ###:

1. [1] 152051-0120 PUMP HOUSING
5. [1] 152100-1120 PUMP PLUNGER
6. [1] 152102-0400 COMPRESSION SPRING
7. [1] 152105-1500 CAPSULE
8. [1] 029332-6030 GASKET
10. [1] 152111-2920 TAPPET
10/2. [1] 152112-1000 ROLLER
10/3. [1] 152113-0100 BEARING PIN
10/4. [2] 152114-0700 SLIDER
14. [2] 152115-0200 VALVE BODY
14. [2] 152115-0200 VALVE BODY
15. [2] 152116-0200 COILED SPRING
15. [2] 152116-0200 COILED SPRING
16. [1] 152117-0400 CAPSULE
18. [1] 029331-6030 GASKET
19. [1] 029631-6060 O-RING
20. [1] 152121-0200 LOCKING WASHER
25. [1] 152200-5420 HAND PRIMER
30. [1] 152300-5020 EYE BOLT
32. [1] 139814-0000 EYE BOLT
35. [2] 139514-0000 GASKET
36. [2] 139514-0000 GASKET

Cross reference number

Zexel num
Bosch num
Firm num
Name
105210-4271 
105210-6530 
9 440 610 033 
1157500180  ISUZU
SUPPLY PUMP
K 14GC FEED PUMP F/P
105210-4271 
105210-6530 
9 440 610 033 
9813500641  ISUZU
SUPPLY PUMP
A K 14GC FEED PUMP F/P
105210-4271 
105210-6530 
9 440 610 033 
1157500740  ISUZU
SUPPLY PUMP
B K 14GC FEED PUMP F/P




Information:

Changing Filter Element
A 1U-9578 Repair Kit (Nozzle Tester) is available to maintain the tester. The repair kit contains a new filter along with seals, gaskets, and instructions on how to use the kit. Do not reuse seals and gaskets when changing the filter. Always use new seals and gaskets.Calibration Fluid
The calibration fluid should be changed every three months or after testing 50 nozzles. The fluid should also be changed whenever inaccurate test results are suspected.Inaccurate test results can be caused by fluid with improper specific gravity, viscosity, visible contamination, fluid that foams, or discolored fluid.The fluid should also be checked for the correct viscosity. It is a good practice to test new calibration fluid for the correct viscosity and specific gravity. Use a 9U-7840 Test Kit to check calibration fluid.
Do not refill the nozzle tester with test oil that has been pumped through a fuel injection nozzle. Nozzles contain residual amounts of diesel fuel that is pumped out when tested. The diesel fuel mixes with and contaminates the test oil. Using this diesel fuel test oil combination will damage the nozzle tester.
9U-7840 Test Kit For Checking Fluid Viscosity Calibration fluid will last longer if the nozzles are cleaned prior to testing. As the fluid in the tester becomes contaminated, the accuracy of the test results are decreased.Changing Calibration Fluid
1. Completely drain the reservoir and any fluid contained in the pump mechanism. Special care must be taken for the disposal of the calibration fluid. Recent regulations prohibit the dumping of oil; all oil must be properly disposed.2. Thoroughly clean the reservoir using an 8T-9011 Component Cleaner or equivalent and clean towels.3. Install a new 8T-5313 Filter Element (10 micron). A new filter element should be installed whenever the calibration fluid is changed (even if less than 3 months).4. Fill the reservoir with clean calibration fluid (refer to the chart for part numbers).Nozzle Tester Pressure Gauges
Pressure gauges in the nozzle tester should be checked for accuracy every 12 months or whenever inaccurate test results are suspected. Gauges should also be checked whenever a gauge is damaged or the needle does not return to zero. Record all data on the data sheets in the "Forms" section.1. Remove pressure gauge from the nozzle tester.2. Install gauge adapter from 5P-8558 Calibrating Group Pressure Gauge onto pressure gauge.3. Connect pressure to tester port.4. Use a 1U-5230 Hand Pump to apply pressure to the gauge. Increase the pressure to 25% of the pressure gauges capacity.5. Check the actual gauge pressure with the tester gauge reading. The two pressures should be within two percent of each other.6. Repeat Step 5 at 50, 75 and 100 percent increments. Each increment should be within two percent of the tester gauge reading.7. If the pressure is not within two percent, the pressure gauge should be replaced.Check Tester For Leakage
Before testing any nozzle, check the tester for obvious external leakage. Leakage in the tester will give inaccurate test results, causing good nozzles to be rejected.Always check the tester for leakage

Have questions with 105210-4271?





Group cross 105210-4271 ZEXEL

Mitsubishi 

9 440 610 874 
NP-FP/KE-AD 
3196182200 
SUPPLY PUMP
 
ME056168 

9 440 610 954 
NP-FP/KE-ADS 
 

Mitsubishi 

9 440 610 846 
NP-FP/KE-A 
3126186400 
SUPPLY PUMP
9 440 610 106 
NP-FP/KE-A 
 
SUPPLY PUMP

Hino 

9 440 610 687 
NP-FP/KE-A 
225601110A 
SUPPLY PUMP
9 440 610 013 
 
SUPPLY PUMP

Isuzu 

9 440 610 078 
9813500611 
SUPPLY PUMP
 
9813500621 
SUPPLY PUMP
 
 
SUPPLY PUMP

Isuzu 

 
1157500410 
SUPPLY PUMP
105210-4271  

105210-6530 
9 440 610 033 
1157500180 
SUPPLY PUMP
105210-4271  

105210-6530 
9 440 610 033 
9813500641 
SUPPLY PUMP
105210-4271  

105210-6530 
9 440 610 033 
1157500740 
SUPPLY PUMP
F 01G 29R 009 
1157500031 
SUPPLY PUMP
9 440 610 483 
1157500340 
SUPPLY PUMP
9 440 611 042 
1157500360 
SUPPLY PUMP
Back to top