105207-1120 ZEXEL 9 440 611 020 BOSCH SUPPLY PUMP 9440611020 1052071120 me066331


 

Information supply pump

BOSCH 9 440 611 020 9440611020
ZEXEL 105207-1120 1052071120
MITSUBISHI ME066331 me066331
105207-1120 SUPPLY PUMP
Rating:
34
Buy SUPPLY PUMP 105207-1120 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
105207-1120 
9 440 611 020 
ME066331  MITSUBISHI
SUPPLY PUMP
* K 14GC F/P




Information:


Table 1
Diagnostic Trouble Codes
J1939 Code and Description CDL Code and Description
4334–20
Aftertreatment #1 DEF #1 Pressure (absolute) : Data Drifted High 3090–20
Aftertreatment #1 DEF Pressure Sensor : Data Drifted High
4334-21
Aftertreatment #1 DEF #1 Pressure (absolute) : Data Drifted Low 3090-21
Aftertreatment #1 DEF Pressure Sensor : Data Drifted Low
3361-5
Aftertreatment #1 DEF Dosing Unit : Current Below Normal 3821-5
Aftertreatment #1 Diesel Exhaust Fluid Dosing Valve Actuator : Current Below Normal
3361-6
Aftertreatment #1 DEF Dosing Unit : Current Above Normal 3821-6
Aftertreatment #1 Diesel Exhaust Fluid Dosing Valve Actuator : Current Above Normal
3516-12
Aftertreatment #1 DEF Concentration : Failure 3100-12
Aftertreatment #1 DEF Tank Fluid Quality Sensor : Failure
Table 2
Event Codes
J1939 Code and Description CDL Code and Description
5392-31
Aftertreatment Diesel Exhaust Fluid Dosing Unit Loss of Prime E1370 (2)
Aftertreatment #1 DEF Dosing Unit Loss of Prime
4334-18
Aftertreatment #1 DEF #1 Pressure (absolute) : Low - moderate severity (2) E931 (2)
Low Aftertreatment #1 DEF Pressure
4334-16
Aftertreatment #1 DEF #1 Pressure (absolute) : High - moderate severity (2) E930 (2)
High Aftertreatment #1 DEF Pressure
3516-16
Aftertreatment #1 DEF Concentration : High - moderate severity (2) E1365 (2)
High Aftertreatment #1 DEF Concentration
3516-18
Aftertreatment #1 DEF Concentration : Low - moderate severity (2) E1364 (2)
Low Aftertreatment #1 DEF Concentration
5246-15
Aftertreatment SCR Operator Inducement Severity : High - least severe (1) E1389 (1)
Aftertreatment #1 SCR Operator Inducement
5246-16
Aftertreatment SCR Operator Inducement Severity : High - moderate severity (2) E1389 (2)
Aftertreatment #1 SCR Operator Inducement
5246-0
Aftertreatment SCR Operator Inducement Severity : High - most severe (3) E1389 (3)
Aftertreatment #1 SCR Operator Inducement Ensure that DEF fluid conforms to specification ISO 22241 requirements and fluid handling, filling, and storage procedures are strictly followed.All transfer equipment and storage containers should be used exclusively for DEF and should not be reused for other fluids. For example coolants, fuels, oils, and windshield washer fluid.If contamination of the DEF system is suspected, refer to Troubleshooting, DEF Concentration is Incorrect. Ensure that the correct troubleshooting steps are followed. To test for contamination of the DEF tank, refer to Systems Operation Testing and Adjusting, Diesel Exhaust Fluid Quality - Test.If the DEF is contaminated, Caterpillar recommends that the DEF tank is flushed. Refer to Systems Operation Testing and Adjusting, Diesel Exhaust Fluid Tank - Flush for the correct procedure.

Have questions with 105207-1120?





Group cross 105207-1120 ZEXEL

9 440 610 732 
NP-FP/K-P 
 
SUPPLY PUMP
9 440 610 065 
NP-FP/K-P 
 
SUPPLY PUMP
9 440 610 818 
NP-FP/K-P 
 
SUPPLY PUMP

Mitsubishi 

105207-1120  
9 440 611 020 
ME066331 
SUPPLY PUMP
F 01G 29R 00H 
NP-FP/K-P 
 

Mitsubishi 

9 440 610 023 
NP-FP/K-P 
ME717123 
SUPPLY PUMP
 
 

9 440 610 134 
NP-FP/K-P 
 
SUPPLY PUMP
9 440 610 976 
NP-FP/K-P 
 
SUPPLY PUMP
9 440 610 577 
NP-FP/K-P 
 
SUPPLY PUMP
Back to top