101340-9010 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1013409010 62156000693d


 

Information injection-pump assembly

ZEXEL 101340-9010 1013409010
ISEKI 62156000693D 62156000693d
101340-9010 INJECTION-PUMP ASSEMBLY
Rating:
10
Buy INJECTION-PUMP ASSEMBLY 101340-9010 zexel genuine, new aftermarket engine parts with delivery

Service parts 101340-9010 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101034-9140
3. GOVERNOR 105419-0280
4. SUPPLY PUMP
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE
7. COUPLING PLATE 156636-0320
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105151-1451
11. Nozzle and Holder
12. Open Pre:MPa(Kqf/cm2) 11.8{120}
13. NOZZLE-HOLDER 105081-3141
14. NOZZLE 105000-1650
15. NOZZLE SET

Include in #1:

101340-9010 as INJECTION-PUMP ASSEMBLY

Cross reference number

ZEXEL 101340-9010 1013409010
ISEKI 62156000693D 62156000693d


Zexel num
Bosch num
Firm num
Name
101340-9010 
 
62156000693D  ISEKI
INJECTION-PUMP ASSEMBLY
E3AB1 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-3-2
Pre-stroke mm   1.95 1.9 2
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 2
Cyl.1-2
deg.   240 239.5 240.5
Injection quantity adjustment
Adjusting point   A
Rack position   13.3
Pump speed r/min   1300 1300 1300
Average injection quantity mm3/st.   47.4 46.4 48.4
Max. variation between cylinders %   0 -2 2
Basic   *
Fixing the lever   *
Injection quantity adjustment_02
Adjusting point   -
Rack position   8.2+-0.5
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   8 7 9
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
 

Test data Ex:

Governor adjustment

Test data 101340-9010
N:Pump speed R:Rack position (mm) (1)Target notch: K (2)RACK CAP: R1 (3)Set idle sub-spring (4)Main spring setting (5)Rack difference between N = N1 and N = N2
----------
K=7 R1=(17.5)mm N1=1300r/min N2=800r/min
----------

Speed control lever angle

Test data 101340-9010
F:Full speed I:Idle (1)Stopper bolt setting
----------

----------
a=18deg+-5deg b=32deg+-5deg

Stop lever angle

Test data 101340-9010
N:Pump normal S:Stop the pump.
----------

----------
a=23deg+-5deg b=46deg+-5deg

Timing setting

Test data 101340-9010
(1)Pump vertical direction (2)Position of gear mark 'Z' at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=22deg
----------
a=(120deg)




Information:

Introduction
Do not perform any procedure in this Special Instruction until you have read the information and you understand the information.DEF injectors are being replaced in the field and returned to Caterpillar for testing. Results of the testing are finding a large portion of the returned DEF injectors are found to be fault not repeated.This form is to be used and filled out in any case that a DEF injector is being replaced.The DEF injector troubleshooting return form needs to be completed and included within failed part returns documenting what was found that led to DEF injector replacement. Attach the photos of DEF injector tip and mount area along with a Product Status Report to the SIMS claim.References
Table 1
Engine Publication Type Media Number
C7.1 Troubleshooting UENR0668
Testing and Adjusting UENR4467
Disassembly and Assembly UENR4468
C9.3 Troubleshooting UENR0978
Testing and Adjusting UENR3402
Disassembly and Assembly UENR0130
C13 Troubleshooting UENR0955
Testing and Adjusting UENR4302
Disassembly and Assembly UENR0131
C15/C18 Troubleshooting UENR0955
Testing and Adjusting UENR3351
Disassembly and Assembly UENR0132 Procedure
What code are you troubleshooting? __________
Follow the correct troubleshooting procedure. Reference Table 1 for correct media number to use.
When troubleshooting procedure requests the DEF quality check, DEF injector resistance measurement, or Dosing Accuracy Test, document those results in Tables 2, 3, and 4.Tables
Table 2
DEF Quality Results
Step Instruction Completed (Yes/No) Result Comments Units
1 Follow the Testing and Adjusting procedure for "Diesel Exhaust Fluid Quality - Test"
2 DEF Contamination Test Pass / Fail
3 DEF Concentration Test % at 20° C (68° F)
Illustration 1 g06175415
Table 3
Injector Resistance Measurement
Step Instruction Completed (Yes/No) Result Comments Units
1 Turn the keyswitch to the OFF position. Allow 2 minutes to elapse before proceeding.
2 Disconnect the DEF injectors from the applicable harness.
3 Inspect the connector for damage and debris.
4 Measure the temperature of the injector (aluminum body). C
5 Connect two 398-4987 Probes to the DEF injector. The connectors must be used to prevent damage to the DEF injector connector. Reference Illustration 1 for example.
6 Measure the resistance of the DEF injector. Ohms
Table 4
Dosing Accuracy Test
Step Instruction Completed (Yes/No) Result Comments Units
1 Follow the Testing and Adjusting procedure for "Aftertreatment SCR System Dosing - Test"
2 Remove the injector from the DPF outlet.
3 Take a photograph of the DEF injector mount on the DPF outlet and the tip of the DEF injector.
4 Install the injector on the beaker.
5 Run the DEF System Dosing Accuracy test through Cat® Electronic Technician (ET).
6 Use the beaker to measure the amount of fluid from the dosing test. ml
7 Repeat the test to verify consistency. ml
8 Install the injector back onto the DPF outlet.