105210-4211 ZEXEL 9 440 610 954 BOSCH 9440610954 1052104211


 

Information

BOSCH 9 440 610 954 9440610954
ZEXEL 105210-4211 1052104211
105210-4211 None
Rating:
12
Buy None 105210-4211 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

1. [1] 152004-0920 PUMP HOUSING
5. [1] 152100-1120 PUMP PLUNGER
6. [1] 152102-0400 COMPRESSION SPRING
7. [1] 152105-1500 CAPSULE
8. [1] 029332-6030 GASKET
10. [1] 152111-2920 TAPPET
10/2. [1] 152112-1000 ROLLER
10/3. [1] 152113-0100 BEARING PIN
10/4. [2] 152114-0700 SLIDER
14. [2] 152115-0100 VALVE BODY
14. [2] 152115-0100 VALVE BODY
15. [2] 152116-0200 COILED SPRING
15. [2] 152116-0200 COILED SPRING
16. [1] 152117-0100 CAPSULE
18. [1] 029331-6030 GASKET
20. [1] 152121-0200 LOCKING WASHER
25. [1] 152200-5420 HAND PRIMER
26. [1] 152207-1800 ADAPTOR
27. [1] 029631-6060 O-RING
30. [1] 152300-6620 EYE BOLT
32. [1] 029731-4080 EYE BOLT
35. [2] 026514-1840 GASKET D17.9&14.2T1
36. [2] 026514-1840 GASKET D17.9&14.2T1
47. [1] 152325-0100 EYE BOLT
48. [2] 029331-6040 GASKET

Include in #1:

101603-1231 as SUPPLY PUMP

Cross reference number

Zexel num
Bosch num
Firm num
Name
105210-4211 
9 440 610 954 
NP-FP/KE-ADS 
   

K 14GC FEED PUMP F/P




Information:

* Remove any carbon deposits from the injection nozzles before disassembling, assembling, or adjusting the injection nozzle assembly. Before disassembling, check the pressure and shape of the spray and inspect the assembly for fuel leakage. Do not disassemble if no defects are evident.* Do not change the needle valve and nozzle combination on each cylinder.
* Assembly sequenceFollow the disassembly sequence in reverse.Service standards Tightening torque (Unit: N m {kgf m}) Special tools (Unit: mm) Inspection before removal
Inspection: Injection nozzle* Connect the injection nozzle to the nozzle tester and carry out the following inspections.
* Before starting the inspections, operate the lever on the nozzle tester two or three times to bleed out all the air.
(1) Checking the valve opening pressure* Push down the lever on the nozzle tester at a rate of one to two seconds per stroke. This will cause the pressure gauge reading to rise gradually, and the needle will suddenly deflect. Note the pressure at which the needle starts to deflect. * If the measurement is out of the standard value range, disassemble the nozzle, clean it, and then adjust it using an adjusting shim.* Available adjusting shims (thickness): 1.2 mm to 1.7 mm (11 different thicknesses in increments of 0.05 mm)* If the valve opening pressure is still incorrect after the adjustment, replace the injection nozzle assembly.
* Do not touch the spray that comes out of the nozzle.
(2) Inspecting the spray condition * Pump the lever on the nozzle at a rate of about one to two seconds per stroke and keep it spraying continuously.A Spray in the form of straight line (Good: spray angle at 10° or less)B Spray angle too large (Bad)C Spray deviates from centerline (Bad)D Irregular spray (Bad)
* Do not touch the spray that comes out of the nozzle.
* Check that no fuel drips from the nozzle after the spray is complete.* If defects are evident, disassemble and clean the injection nozzle, and then inspect its spray condition once again.* If defects persist after reinspection, replace the injection nozzle assembly.(3) Checking for leakage * Decrease the nozzle pressure to a pressure 1960 kPa {20 kgf/cm2} lower than the first valve opening pressure. Maintain this pressure for 10 seconds and check that no fuel drips from the end of the nozzle.* If fuel drips are evident, disassemble and clean the injection nozzle, and then perform a leakage test once again.* If leakage is detected during the reinspection, replace the injection nozzle assembly.Removal procedure
Removal: Injection nozzle
* Do not touch the sliding surfaces of the needle valve. If you accidentally touch it, clean it with a cleaning fluid (such as gas oil).* Do not change the needle valve and nozzle combination on each cylinder.
Cleaning procedure
Cleaning: Injection nozzle* Wash the needle valve and nozzle in a cleaning fluid (such as gas oil), then use
to remove any carbon deposits according to the following procedure. * Remove carbon deposits from the tip of the needle valve using the clean bar of
.
* Do not use a wire brush

Have questions with 105210-4211?





Group cross 105210-4211 ZEXEL

Mitsubishi 

9 440 610 874 
NP-FP/KE-AD 
3196182200 
SUPPLY PUMP
 
ME056168 

105210-4211  
9 440 610 954 
NP-FP/KE-ADS 
 

Mitsubishi 

9 440 610 846 
NP-FP/KE-A 
3126186400 
SUPPLY PUMP
9 440 610 106 
NP-FP/KE-A 
 
SUPPLY PUMP

Hino 

9 440 610 687 
NP-FP/KE-A 
225601110A 
SUPPLY PUMP
9 440 610 013 
 
SUPPLY PUMP

Isuzu 

9 440 610 078 
9813500611 
SUPPLY PUMP
 
9813500621 
SUPPLY PUMP
 
 
SUPPLY PUMP

Isuzu 

 
1157500410 
SUPPLY PUMP
9 440 610 033 
1157500180 
SUPPLY PUMP
9 440 610 033 
9813500641 
SUPPLY PUMP
9 440 610 033 
1157500740 
SUPPLY PUMP
F 01G 29R 009 
1157500031 
SUPPLY PUMP
9 440 610 483 
1157500340 
SUPPLY PUMP
9 440 611 042 
1157500360 
SUPPLY PUMP