105952-1692 ZEXEL 9 420 610 688 BOSCH ACTUATOR 9420610688 1059521692 223009052a


 

Information actuator

BOSCH 9 420 610 688 9420610688
ZEXEL 105952-1692 1059521692
HINO 223009052A 223009052a
105952-1692 ACTUATOR
Rating:
13
Buy ACTUATOR 105952-1692 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

1. [1] 159560-1200 GOVERNOR HOUSING
2. [8] 139006-4100 BLEEDER SCREW
4. [1] 159564-0000 COILED SPRING
5. [1] 159564-4000 SLOTTED WASHER
6. [1] 159564-4100 SLOTTED WASHER
7. [1] 159564-7321 CONNECTOR
8. [1] 020105-1240 BLEEDER SCREW M5P0.8L12
9. [1] 159564-0501 PLATE
9B. [1] 159564-6500 PLATE
9C. [1] 159584-5200 PLATE
10. [1] 020105-1240 BLEEDER SCREW M5P0.8L12
11. [1] 159569-8822 ACTUATOR
12. [2] 020106-4040 BLEEDER SCREW
13. [1] 159561-0700 GOVERNOR COVER
14. [4] 010006-7040 BLEEDER SCREW M6P1L70
15. [2] 010006-5540 BLEEDER SCREW M6P1L55 4T
16. [8] 014110-6440 LOCKING WASHER
16. [8] 014110-6440 LOCKING WASHER
16. [8] 014110-6440 LOCKING WASHER
16. [8] 014110-6440 LOCKING WASHER
17. [1] 154371-5600 GASKET
18. [1] 154390-0400 GASKET
19. [1] 154390-0500 GASKET
20. [1] 153021-6300 CAP
21. [1] 026524-3040 GASKET
22. [1] 029731-4680 EYE BOLT
23. [2] 139514-0300 GASKET
27. [2] 139006-1300 BLEEDER SCREW M6P1L76
80. [1] 159584-1600 TOOTHED GEAR
81. [1] 014111-2420 LOCKING WASHER
82. [1] 013031-2120 UNION NUT
83. [1] 025803-1310 WOODRUFF KEY
900S. [1] 025803-1310 WOODRUFF KEY
901S. [1] 025803-1610 WOODRUFF KEY

Include in #1:

106971-3212 as GOVERNOR

Cross reference number

Zexel num
Bosch num
Firm num
Name
105952-1692 
105952-1693 
9 420 610 688 
223009052A  HINO
ACTUATOR
* K




Information:

Caterpillar's Scheduled Oil Sampling (S*O*S) analysis is the best indicator for determining what is happening inside your engine.S*O*S analysis is a diagnostic tool used to determine oil performance and component wear rates. S*O*S analysis uses a series of tests designed to identify and measure contamination such as:* soot, sulfur, etc.* degradation such as the presence of fuel, water and antifreeze in a sample of oil.* the amount of wear metals present in the oil sample.Wear metal present in the oil sample are compared to established Caterpillar norms to determine acceptability. S*O*S analysis must be performed on a continuing basis to be effective as an indicator. Intermittent sampling does not allow wear rate trend lines to be established.Obtain S*O*S samples at regularly scheduled intervals to monitor the condition and maintenance requirement of your engine. Each oil sample should be taken when the oil is warm and well mixed to ensure that the sample is representative of the oil in the engine crankcase.Consult your Caterpillar dealer for complete information and assistance in establishing an S*O*S analysis program for your engine(s).S*O*S Analysis
S*O*S analysis is composed of three basic tests:* Wear analysis* Chemical and Physical Tests* Oil Condition Analysis Wear analysis is performed with an atomic absorption spectrophotometer to monitor component wear by identifying and measuring concentrations, in parts per million, of wear elements present in the oil. Based on known normal concentrations data, maximum limits of wear elements are established. Impending failures can be identified when test results deviate form concentration levels established as acceptable, based on normal wear. Chemical and Physical Tests detect the presence of water, fuel and glycol (antifreeze) in the oil and determine whether or not their concentrations exceed established maximum limits. Oil Condition is evaluated with infrared analysis. This determines the presence and measures the amount of contaminants such as soot, sulfur products, oxidation, and nitration products in the oil. Infrared analysis can also assist in customizing (reducing, maintaining or extending) oil change intervals for particular conditions and applications.Infrared analysis should always be accompanied by wear element analysis and chemical and physical test to assure accurate diagnosis. Infrared analysis must be used to determine oil change intervals. S*O*S analysis must include Infrared (IR) in the analysis.The test results of the oil samples will then be used as a basis for determining the oil change interval for your engine, giving you the ultimate time between oil changes without the risk of engine damage.Refer to Caterpillar pamphlet Listen To Your Oil (PEDP1129) for information and benefits of S*O*S analysis.

Have questions with 105952-1692?





Group cross 105952-1692 ZEXEL

Hino 

 
223009050A 
ACTUATOR
 
223009051A 
ACTUATOR
105952-1692  

105952-1693 
9 420 610 688 
223009052A 
ACTUATOR
 
 
ACTUATOR
F 01G 29N 07C 
 
ACTUATOR
F 01G 29N 07D 
 
ACTUATOR
Back to top